Hi everyone, I am Daniela, the SolidWorks PDM SME for SPK and Associates. Today, we’ll be detailing SolidWorks help for the infamous “unable to locate the file” message and how to fix it.

SolidWorks Help: Unable To Locate The File

SolidWorks “unable to locate the file” error message pops up pretty often. It can happen when you have an assembly, a drawing, a file that references a part that has:

  1. Been moved,
  2. Been renamed.

Essentially, something’s been changed and that reference is now broken.

With drawings and assemblies it’s particularly straightforward to relink or replace the relationship. However, in the case we’re demonstrating in the video, this is popping up for a part. And, with a part it’s trickier to remedy

SolidWorks Help: Fix Assembly Error “Unable To Locate The File”

In instances where we see this message and it relates to a part, you can follow these SolidWorks help steps to fix it.

  1. Click ‘suppress all missing components’ to bypass.
  2. Note that because this is affecting the part level, if you use this part in an assembly or in a drawing, this message will populate for the drawing and assembly, anywhere this file this part file is used.
  3. This is why it’s important to fix it at the part level first.
  4. Let’s proceed. Now click ‘suppress all missing components’ and let me click out of here. 
  5. Now check it looks like a normal part. 

SolidWorks Help: Fix Part Error “Unable To Locate The File”

While we saw that link to an assembly, there is no assembly referenced in the feature tree. This can make it tricky to find.

If you see a question mark next to one of the features in the feature tree, there’s an outside external reference. For SolidWorks help to fix this:

  1. Click on the main body, then right click.
  2. In the drop down menu, select ‘external references’. As you can see in the video this part was likely made in context of the assembly using an edge. This is why it is referencing this assembly can’t be found. Because it is on a user’s desktop.
  3. Rather than track this assembly down, we’re going to remove the standalone element of this part file – it does not need that edge anymore.
  4. You need to break this reference.
  5. Select the feature and click ‘break selected.’
  6. Now, you’ll see a warning advising the reference will be permanently broken.
  7. Click ‘ok’.
  8. Click ‘close’. You’ll now see the status has been updated to broken.
  9. Save those changes. 

Now, that should be fixed. The next time you open the file, the “unable to locate file message” should no longer be there. 

Conclusion

Fixing the SolidWorks “unable to locate the file” message requires you to find which reference is broken. When this is impacted at part level, it is important to fix the part. In doing so, it prevents the error message appearing on all drawings or assemblies where that part has been used. 

Subscribe to our YouTube channel for even more SolidWorks PDM help, tricks and tips!

Looking for further support and SolidWorks PDM help? Contact our experts today.

Latest White Papers

The Ultimate Jira Data Protection

The Ultimate Jira Data Protection

Remote work is here to stay, and companies are turning to cloud-based solutions to support their teams. Atlassian's suite of products is a top choice for businesses worldwide. But, many businesses are still unsure about its built-in data protection capabilities....

Related Resources

Solidworks Error: No Database Attached To This View – Part 2

Solidworks Error: No Database Attached To This View – Part 2

Hi everyone, I am Daniela, the SolidWorks PDM SME for SPK and Associates. Today, I’ll be showing you how to fix the SolidWorks error message “no database is connected to this view.”  This video is split in to two parts. Check out part one here. You can watch the video...

Virtual CAD (vCAD) Updates 2023, Q2

Virtual CAD (vCAD) Updates 2023, Q2

Our team at SPK are dedicated to continually evolving the virtual CAD (vCAD) user experience and security features. And, we have three new exciting feature releases for vCAD updates 2023. Check them out below. Create Images Are Now Self-Serve In vCAD The ability to...

SolidWorks PDM Error: No Database Attached to this View Part 1

SolidWorks PDM Error: No Database Attached to this View Part 1

Hi everyone, I am Daniela, the SolidWorks PDM SME for SPK and Associates. Today, I’ll be showing you how to fix the SolidWorks error message "no database is connected to this view."  This video will be split in to two parts. You can watch the video as Daniela walks...